The following information must be provided with an application for building rules consent for building work that involves the installation, alteration, relocation or removal and reinstatement of roof trusses.

A structural design report that includes:

  • the name of the software program or standards used
  • truss spacing
  • top and bottom chord restraint spacing
  • overhang, eaves type and fascia type
  • roofing and ceiling type.
  • roof pitch
  • the inputs and discretionary parameters used in the design, for example:
    • importance level for building type
    • wind load and internal pressure coefficient
    • special loads or conditions considered, such as:
      • water tank
      • air-conditioner
      • solar system
      • corrosion
      • attached structures

Drawings showing:

  • roof frame layout plan showing truss locations, spans, station for truncated girder truss
  • layout plans of wall framing and floor framing
  • girder truss locations, boot details and lateral restraint
  • top chord bracing details – layout and fixing
  • top chord restraint – spacing, fixing and splicing, intermediate ties for valley truss
  • bottom chord restraint – spacing, size and bracing, direct fix
  • tie down details and location
  • overhang details – eave supported or non-supported, structural or non-structural fascia
  • hip end framing and connection details
  • gable end truss – supported or free spanning
  • bearing widths (70 mm minimum)
  • details including truss to truss connections, web bracing, non-load bearing braced wall connections, internal supports or tie downs, laminations
  • special loads such as solar heating, air-conditioning, hot water service or attached structures
  • concentrated or critical load paths to support framing (including girder trusses) and internal load bearing walls or supports.

Details showing:

  • Trusses:
    • elevation of each truss showing dimensions, member layout, connections, support points (at panel points), web bracing (including details), lamination details, critical design information
    • details indicating support points (correlating with framing layout plans)
    • girder truss – imposed loads are detailed and accounted for
    • loads and connections from conventional roof have been accounted for and certified by structural engineer
    • details to show that the existing structure is adequate to support new roof
  • Hybrid roof and additions:
    • loads and connections from conventional roof have been accounted for and certified by structural engineer
    • details to show that the existing structure is adequate to support new roof.

The Minister’s Schedule 8 List of Roof Truss Information is determined for the purposes of section 119(1)(c) of the Planning, Development and Infrastructure Act 2016 and Schedule 8 Clause 4(7) of the Planning, Development and Infrastructure (General) Regulations 2017.